Elite PLC and Elite 200/500

The DiaLog Elite is a flexible and powerful solution for monitoring the critical operations of a small or large plant with PLCs or SCADA systems.

The Elite PLC and Elite 200 are designed to interface directly to PLCs and SCADA systems via a simple serial connection cable. The Elite PLC offers a combination of physical I/O and Modbus RTU communication totaling up to 72 monitored/controlled points. The Elite 200/500 only supports communication over Modbus RTU for 200 or 500 monitored/controlled points.

Both units operate as Modbus Masters to read values from PLCs or from SCADA systems. In addition, each supports being a Modbus Slave to a SCADA system.

The Elite PLC and Elite 200/500 provide a local user interface to view/change conditions monitored and controlled by the PLC. The Elites can automatically compute and log the pump run-times and cycles as well as totalized flow. This information can be viewed locally or retrieved remotely via phone, via modem connection from a PC or even directly to the Internet.

Typical conditions that are monitored and provide alarm notification:

  • High alarm from either a float or a level sensors
  • Pump failure indicated by each motor starter failures, over temperature or seal failure
  • Loss of power
  • Amperage to each motor
  • VFD failures
  • Bar screen motor, settling tank pump, and effluent pump failures
  • Personnel access to station - when on-site and total time on-site
  • Intrusion
  • Communication between the PLC or SCADA and the Elite

Typical conditions that are monitored and reported for information purposes only:

  • Run-times and run cycles for 2-16 pumps
  • Tank levels are continually logged to provide a profile of station activity
  • Log and retrieve daily pump cycles and run-times for weeks
Elite PLCElite 200/500
High alarms from float or sensor
Loss of power (2-phase)
Loss of power (3-phase) from phase monitor
Pump failures indicated by motor starter
Pump run-times and cycles for pumps
Tank level from level sensors
Remote control of pumps
Remote control VFD settings
Interface to PLCs
Interface to SCADA

Landline-based systems

Alarm notification

  • Up to 512 phone/pager numbers
  • User-recorded voice messages

Remote capabilies

  • Call-in to receive current conditions, pump run-times and cycles
  • Programming via phone
  • Control relays for pump activation
  • Change control settings in the PLC via phone or remote PC

Cell-phone-based systems

Alarm notification

  • Up to 512 numbers
  • User-recorded voice messages
  • Phone, cell, pager, fax and modem

Remote capabilities

  • Call-in to retrieve current conditions, pump run-times and cycles
  • Modem call-in to retrieve current conditions, pump run-times, cycles, logged data and event log
  • DiaLogOnline internet service automatically retrieves and displays current conditions, pump run-times, cycles, logged data and event log
  • Programming via phone or PC via modem
  • Control relays for pump activation or change other settings in the PLC or SCADA